Send Message
Lanry Instruments (Shanghai) Co., Ltd.

Lanry Instruments (Shanghai) Co., Ltd.

 

Specialize In Ultrasonic Flowmeter More Than 20 Years!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsClamp On Ultrasonic Flow Meter

The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC

The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC

  • The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC
The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC
Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE CPA
Model Number: TF1100-EC
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton package
Supply Ability: 50pcs/day
Contact Now
Detailed Product Description
Product Name: Water Ultrasonic Flow Meter TF1100-EC Output: 4-20mA /Modbus
High Temp: -35-200 °C Application: Measuring Fluid
Temperauture Input Sensor: Clamp On PT1000 Single Gross Weight: 7.0 Kg
High Light:

clamp on type ultrasonic flow meter

,

ultrasonic fuel flow meter

The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC

 

Fuel Oil Water ultrasonic Flow Meter works on the transit-time principle. The clamp-on ultrasonic sensors are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

 
The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC Features:
 
1. Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt.
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function.
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

Application
 

General

 

1. Support of commissioning process and installation

2. Energy efficiency audits
3. Service and maintenance

4. Replacement of defective devices

5. Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

 

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Food , beverage and pharmaceutical industry
Refrigeration and air conditioning systems
Power supply
Metallurgy and mining applications

 

Specifications: Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -10℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
Security Keypad lockout, system lockout
Size 244*196*114mm
Weight 2.4kg
 
 
 

Specifications: Transducer

 

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size Type S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*32(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducer Aluminum for standard temp. sensor, and peek for high temp. sensor
Cable Length Std:10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 
 
S 48(h)*28(w)*28(d)mm
M 60(h)*34(w)*32(d)mm
L 80(h)*40(w)*42(d)mm
 
 
 
Packing & Delivery
Packing

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

 
The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC 0The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC 1The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC 2
 

Delivery

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

 

The Professional Fuel Oil Water ultrasonic Flow Meter modbus output TF1100-EC 3

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)